Select information on Xandex inking products by choosing an inking application tab. If you do not see your equipment or application listed, please contact Xandex Customer Service.
Acces PDF Uf300 Prober Manual Uf300 Prober Manual When people should go to the book stores, search introduction by shop, shelf by shelf, it is essentially problematic. This is why we offer the books compilations in this website. It will definitely ease you to see guide uf300 prober manual as you such as. It is the prober with high-speed probing that targets non-memory device. Probing Machine: UF2000 Most significant machine model for 200mm wafers High precision, high rigidity machine. International B2B marketplace for surplus and used assets. This manual describes the assembly and installation of a TSK UF200AL/UF300/UF300A. Top Load Prober Interface. This interface is for use with a 0.187” thick prober interface. Board (PIB) (board thickness can range between 0.175 and 0.200 inches). Interface kit information included in this manual: TSKUF200AL/UF300/UF300A Top.
Xandex offers three inker types for high speed inking applications. Series 600 inkers incorporate a high-speed solenoid for use with DM-1 cartridges. The pneumatic Series X1000 & X4000 use DM-2 cartridges to afford a wide range of dot sizes at any speed. The Motorized-Z inker enables motorized z height adjustment and incorporates small dot and large dot modes, which allow dot sizes from 6-50 mil. All inkers feature flip up manipulators and an X,Y adjustment joystick. The low profile X5100 installs in the optical bridge on the listed EG probers. Off-Line inkers are also suitable for Post-Probe inking.
Prober Model | Pneumatic | Electric |
---|---|---|
EG 1034, 2001, 2010, 4060, 4080, 4085, 4090 | X1100: part #340-1100 X4115 (Motorized-Z): part #340-4115 | EG 601: part #330-0601 |
EG 4060, 4080, 4090 | X5100: part #340-5100 | |
KLATEL 1007, 1011, 1200, 1220 | X1200: part #340-1200 X4215 (Motorized-Z): part #340-4215 | KLA 603: part #330-1603 |
The inverted Series 200 mounts underneath the probe ring. Post-Probe inkers also provide sufficient clearance for most Overhead Testing applications.
Tester Model | Prober Model | Electric |
---|---|---|
Sentry 7, 10, 20, 21 | EG | EG 201; part #330-0201 |
Teradyne J937, J941 | All Probers | Cartridge Holder H1-24B7 (retro Teradyne Base): part #310-1222 |
Xandex offers four inkers for post probe inking. All inkers are also suitable for some Overhead Testing & high-speed Off-Line Inking. Inker Model X1412 designed for the TSK APM 90 or UF200 series probers fits on the existing inker mount. Inker X5100 designed for the EG 40X0 series probers fits in the Optical Bridge. X5200 Series designed for the TEL P8 probers mounts on the Optical Bridge, or on the SACC Arm. All inkers allow dot range of 15-50 mil and utilize DM-2.3 cartridges.
Prober Model | Pneumatic |
---|---|
EG 4060, 4080, 4090 | X5100: Part #340-5100 |
TEL P8, P12 | X5200 SACC Arm: Part #340-5200 X5210 Bridge: Part #340-5210 |
TSK APM90, UF200, UF300 | X1412: Part #340-1412 |
Uf300 Prober Manual 2017
Xandex offers electric and pneumatic inkers for cabled probing. Series 100 provides vertical positioning via slide bracket and adjustment knob. Coarse X, Y adjustment and quick inker removal is accomplished by loosening one knob that holds the inker to its mounting plate. The joystick in Series 300 provides fine X, Y adjustment. Series 600 is the only high speed electric inker. Use DM-1, or DM-1.25 cartridges. For 5 mil applications, use an H2 model holder (with plunger adjustment) instead of an H1. Series X1000 are pneumatic inkers, suitable for high-speed application and utilize DM-2 cartridges.
Prober Model | Pneumatic | Electric |
---|---|---|
EG 1034, 2001, 2010, 4085 | X1100: part #340-1100 | EG 101: part #330-0101 EG 301: part #330-0301 EG 601: part #330-0601 |
EG 4060, 4080, 4090 | X1103: part #340-1103 | |
KLATEL 1007, 1011, 1200, 1220 | X1200: part #340-1200 | KLA 103: part#330-1103 KLA 30:; part #330-1303 KLA 603: part #330-1603 |
PWS All Models | PWS 102: part #330-2102 PWS 302: part #330-2302 | |
Teledyne TAC all models: | see retrofits | |
TSK APM3000, APM5000, APM6000, APM7000 | TSK 104: part #330-3104 TSK 604: part #330-3604 |
Many optical inspection applications require retrofit of an existing manipulator and do not use a complete Xandex assembly. DieMarker™ is a hand-held pneumatic inker, which may also be used for any application requiring manual inking (i.e. edge die, packaged devices). Use DM-2 cartridges for DieMarker™ and DM-1, DM-1.25, or DM-S for all other models.
Inspection Station | Pneumatic | Electric |
---|---|---|
All Models | X901 DieMarker: part #340-0901 kit includes hand held pen, foot switch and controller | |
Alessi REL 4500 | H1-12A7: part #310-1112 | |
AT 2400 | H1-24A7: part #310-1212 | |
Mechanization Associates all models (retrofit) | H1-12A7: part #310-1112 | |
Nikon Optiphot | NI 101: part #330-9401 | |
Nikon Optipad | LT 105: part #330-0105 | |
Scientific Instruments all models | LT 105: part #330-0105 | |
Viking Semiconductor all model (retrofit) | H1-24A7: part #310-1212 |
Analytical probers have limited inker clearance due to high-powered microscope objectives and multiple probers. Most analytical probers require retrofit of an existing micromanipulator, and do not use a complete Xandex assembly (see also Retrofits). Use DM-1 or DM-1.25 cartridges.
Prober Model | Electric |
---|---|
Karl Suss PAC6 | B101: part #320-0101 H1-12A7: part #310-1112 |
Micromanipulator - all models (retrofit) | H1-12A7: part #310-1112 |
Signatone - all models (retrofit) | H1-12A7: part #310-1112 |
Wentworth Labs - all models (retrofit) | H1-12Z7: part #310-1192 |
Laser trimming applications require the inker to rest at a very shallow angle under the microscope lens and the lasers. For sufficient clearance, inkers may have a 'side arm' style holder mounting rather than the typical slide bracket. Use DM-1, DM-1.25, or DM-S cartridges.
Laser Trimming Model | Electric |
---|---|
General Scanning M310 | LT 611: part #330-0611 |
Teradyne M1118, M218 | LT 105: part #330-0105 |
LTX/ESI 80, 44 | LT 106: part #330-0106 |
Cartridge holders are available to retrofit most other manufacturers’ inkers. To order, specify body style, coil voltage, connector type, and plunger size. Use DM-1 or DM-1.25 cartridges. Retrofit all H-style holders with a Plunger Stop Assembly for 5 mil dot applications.
Application | Prober Model | Electric |
---|---|---|
EG PI-500 | EG | H14-24A7: part #314-0006 |
PWS 7733 | PWS | H1-24A6: part #310-1211 |
Rucker & Kolls all models | KLA/TEL | H1-24C7: part #310-1232 |
all others | H1-24A7: part #310-1212 | |
Teledyne TAC 14031, 14032, 14033, 71146, 71154 | Teledyne TAC | H4-12D6: part #310-4141 |
KLA/TEL YN 12, YN 27 | KLA/TEL | H1-24C7: part #310-0004* |
KLA/TEL YN 12, YN 27 | KLA/TEL | S2-22C10: part #315-0003 |
KLA/TEL YN 12, YN 27 | TEL P8, P12 | S3-12C10: part #315-0008 |
TEL P8, straight | TEL | S3-12C10: part #315-0010 |
TEL P8, 90 degrees | TEL | S3-12C10: part #315-0011 |
TSK 300 | EG | H6-24A7: part #310-6212 |
TSK 300 | TSK | H6-24Z7: part #310-6292 |
TSK APM90 | TSK | S2-22Z10: part#315-0005** |
Application | Prober Model | Pneumatic |
TSK APM88 | TSK | X1411: part #340-1411*** |
* requires special DM-0.6 cartridge
** complete inker kit is also available. see post-probe inking.
*** retrofit includes pneumatic controller.
Uf300 Prober Manual Free
- Most significant machine model for 300mm wafers
High precision, high rigidity, high throughput machine. - Better cost performance for 300mm wafers.
- 300mm Framed wafer & CSP handling machine.
- It is the prober with high-speed probing that targets non-memory device.
- Most significant machine model for 200mm wafers
High precision, high rigidity machine. - Highly efficient, High throughput, wafer & CSP handling machine.
Better cost performance machine. - High-speed machine for discrete.
- 200mm Framed wafer & CSP handling machine
- Accretech Probing Machine for full wafer testing on a single touch down. Developed with capability to simultaneously measure on 12 stages with dedicate XY stage and POGO tower.
- Consolidated management of the operation of probing machines for higher operation rate.
- This network allows you to consolidate the management of resources with the user host.
- The GEM Network System supports standards based on the SEMI standards to achieve factory automation at customers.
- This is a group of dedicated terminals for increasing the efficiency of test areas.